HISTORICAL VERSIONS
Below is a partial list of standards that have been superseded by newer versions. All NOCSAE standards are continually updated as new data is received.
Historical Versions of ND200
ND200-18
Effective February 2019
Revision
- Removed COR requirement for baseball projectile Section 13.1.1.
ND200-17am18
Effective June 2018
Revisions
- Reduced equipment level from 3 to 2 in Section 1.1.
- Increased pass/fail criteria from 90 lb-f to 112 lb-f in Section 14.1.2.
- Included a system check for the upper and lower load cells and added an upper range to the allowable load cell response (150 lb.-f) in Section 11.2.
ND0200-21
Effective February 2023
Revisions
- Eliminated use of the upper and lower load cells and their associated pass/fail criteria
- Random impact locations updated to impact the cardiac silhouette while shifting the protector instead of moving the NTS.
- Added definitions for Torso Length and Extent of Protective Coverage
- Added requirement that manufacturers shall provide the Torso Length of the person the submitted sample is intended to fit.
ND200-19
Effective July 2019
Revision
- Added requirement to place logo on the primary protective component.
Above is a partial list of standards that have been superseded by newer versions. All NOCSAE standards are continually updated as new data is received.